Analisis Neraca Energi, Self-Consumption, dan Efektivitas Ekonomi PLTS On-Grid 356,4 kWp dengan Skema Layanan Pihak Ketiga di Universitas Negeri Manado
Keywords:
Energy balance, inverter availability, photovoltaic service model, self-consumption, techno-economic evaluationAbstract
Abstract — This study evaluates the energy utilization and economic effectiveness of a 356.4 kWp grid-connected photovoltaic system at Universitas Negeri Manado (UNIMA) under a third-party service model. The analysis combines a pre-PV electricity-cost baseline, FusionSolar plant and inverter reports for 2023-2026, PLN import-export bills, PV service invoices, and contractual documents. The 2023 period is used as a healthy-operation reference, with annual production of 466.517 MWh, specific energy of 1,308.97 kWh/kWp, and a performance ratio of 75.71%. In 2024, PV production remained 433.375 MWh, but only 63.87% was directly self-consumed; 36.13% was exported. Physical export reached 156.596 MWh while 101.786 MWh was credited as an energy offset in PLN billing, producing a 54.810 MWh settlement gap. The credited export therefore constituted one component of the reduction in the PLN bill rather than a separate cash payment from PLN. Although the average PLN bill decreased by 32.74% relative to the 2021 baseline, the combined PLN and PV-service cash-out averaged Rp66.753 million/month, 22.27% above the baseline. Production then declined sharply to 154.382 MWh in 2025 and 34.561 MWh during January-August 2026. PLN invoices for January-June 2026 recorded 284.789 MWh of grid purchases and Rp228.315 million in current-month bills. Because the 2026 invoice format no longer displays PV export/offset fields, zero export cannot be inferred. The results indicate that direct PV use, export credits, load matching, settlement rules, service costs, and inverter availability jointly determine the economic effectiveness of institutional PV.
Keyword — Energy balance, inverter availability, photovoltaic service model, self-consumption, techno-economic evaluation
Abstrak — Penelitian ini mengevaluasi pemanfaatan energi dan efektivitas ekonomi PLTS on-grid 356,4 kWp Universitas Negeri Manado (UNIMA) pada skema layanan pihak ketiga. Analisis menggabungkan baseline biaya listrik sebelum PLTS, Plant/Inverter Report FusionSolar 2023-2026, rekening impor-ekspor PLN, invoice layanan PLTS, dan dokumen kontrak. Tahun 2023 digunakan sebagai healthy-operation reference dengan produksi 466,517 MWh, specific energy 1.308,97 kWh/kWp, dan performance ratio 75,71%. Pada 2024 produksi masih 433,375 MWh, tetapi hanya 63,87% yang digunakan langsung dan 36,13% diekspor. Ekspor fisik mencapai 156,596 MWh, sedangkan 101,786 MWh dikreditkan sebagai offset energi pada rekening PLN sehingga terdapat settlement gap 54,810 MWh. Kredit ekspor tersebut menjadi salah satu komponen pengurang tagihan PLN, bukan pembayaran tunai terpisah dari PLN kepada UNIMA. Walaupun rata-rata tagihan PLN turun 32,74% terhadap baseline 2021, total cash-out PLN dan layanan PLTS mencapai Rp66,753 juta/bulan atau 22,27% di atas baseline. Produksi kemudian turun menjadi 154,382 MWh pada 2025 dan 34,561 MWh pada Januari-Agustus 2026. Rekening PLN Januari-Juni 2026 mencatat pembelian energi jaringan 284,789 MWh dan tagihan bulan berjalan kumulatif Rp228,315 juta. Karena format invoice 2026 tidak lagi menampilkan kolom ekspor/offset PLTS, ketiadaan kolom tersebut tidak dapat ditafsirkan sebagai ekspor nol. Hasil menunjukkan bahwa konsumsi langsung PV, kredit ekspor, kesesuaian waktu produksi-beban, mekanisme settlement, biaya layanan, dan availability inverter secara bersama menentukan efektivitas ekonomi PLTS institusional.
Kata kunci — Availability inverter, evaluasi tekno-ekonomi, model layanan plts, neraca energi, self-consumption